Product ID:ICP-TY-9000
Specification and technical parameter
Item | Indicator |
Detection substrate | Fe |
Detection time | According to the type of test sample, usually it is about 25S. |
Optical system | Palmer type - runge Rowland circle full spectrum vacuum type optical system |
Wavelength range | 130 ~ 800nm |
Focal length | 400mm |
Detector | high-performance CCD array |
Electrode | Tungsten material spray electrode |
Analytical gap | Sample Stage Analytical gap:3.4mm |
Operating temperature | (10 ~ 35)°C |
Storage temperature | (0 ~ 45)°C |
Operating humidity | 20% ~ 80% |
Argon purity requirements | 99.999% |
Argon gas inlet pressure | 0.5MPa |
Argon flow | Stimulating flow is about 3.5L/min, maintaining flow is about 0.4L/min. |
Stimulating max power | 400VA |
Light source type | brand new adjustable digital light source, high energy preliminary combustion science (HEPS) |
Discharge frequency | 100-1000 Hz |
Discharge current | Max 400A |
Spark Stand aperture | 13mm |
Vacuum system | Vacuum software automatically control and monitor |
Working power | 220V AC, 50/60Hz, the single-phase power supply of protective grounding |
Instrument dimensions | 860*720*500 |
Instrument weight | 80kg |
Optical system
l full spectrum optical system of Palmer type - runge structure
l Maximum wavelength range: 130 ~ 800nm
l Multiple high performance CCD detector
l Integrated optical chamber process molding, resistant to change of environment temperature
l Vacuum light chamber design guarantees C, S, P, could achieve the best performance.
l light room temperature control, constant temperature is 35 °C
l Directed type optical technology and lens MgF2 materials ensure that the best energy of UV wavelength of C, S, P.
Sample excitation stage
l Integrated gas circuit and jet electrode technology;
l The optimized argon gas path design ensures the effective cooling of the excitation stage and the metal dust generated during the excitation process effectively enters the filter; makes the sample excitation more stable, and greatly reduces the human body's intake of metal dust, which is beneficial to protect the operator Health and safety;
l Smaller excitation space, so that argon consumption is smaller;
l Easy to use sample fixture
l With electrode self-purge function, the electrode has longer service life and easier to clean the electrode
l 13 mm excitation aperture is more conducive to sample analysis
l The open sample excitation stage can be adapted to the analysis of samples of various sizes and more shapes (including wires);
l SLR lens device design, ordinary personnel can easily maintain the excitation table and clean the lens
Excitation light source
l Brand new adjustable digital light source, the highest frequency can reach 1000Hz;
l High-energy predictive technology (HEPS);
l Optimized design of control and power circuit, perfect excitation safety protection function
l Provide the best spark, arc or combined excitation waveform for different analysis targets
l Discharge current: 400 A maximum
Data collection system
l High-performance ARM data processor with ultra-high-speed data acquisition and control functions
l High-performance CCD solid-state detection technology, full spectrum reception within the band;
l External computer (user-selected)
l FPGA and high-speed data communication technology, powerful data read-in function, short overall test data read-in time
Analyzing Software
l Multi-language CCD full-spectrum graphical analysis software based on Windows system, convenient and practical
l Fully managed to control the entire measurement process and provide users with powerful data processing capabilities and test report output capabilities
l The instrument can be configured with multiple factory calibration curves and more material analysis and advanced solutions
l The software implements algorithms for full-spectrum detection, smart interference, dark current, background and noise, and improves the analysis capabilities of the instrument
l Complete automatic system diagnosis function
l Complete database management functions, convenient for querying and summarizing data
l Intelligent calibration algorithm to ensure the stability and reliability of the instrument
l Complete spectral line information and interference deduction algorithm to ensure more accurate instrument analysis
l Adapt to the latest Windows operating system
Contact: Harry
Phone: 00852-82283663
E-mail: info@lab-kits.com