Homogenizer

Homogenizer
LAB-13010-00

Fast, effective and reproducible homogenization of a wide range of samples, including hard to lyse tissues and cells. It also holds extraordinary powerful for the processing of even impact resistant samples such as bones or cartiage.

The Bioprep-24 is an ideal solution for releasing DNA, RNA, proteins, enzymes, etc. from very tough samples while still retaining molecular integrity.

 

Features 

 1. "3D Rotating High Speed Motion" for quick disruption of those fibrous tissues and resistant cells

2. 50 Programmable memory settings and user optional condition settings

3. A wide range of rotation speed settings from 4.0 m/s to 7.0 m/s, increment 0.05 m/s

4. Brushless motor realizing no brush particle generation and no brush replacement

5. Easy to remove sample tube holder and easy to fix sample tubes with the turn of the central knob

6. Easy to monitor the disruption process through the clear lid

7. Simultaneously homogenize either 24x2ml / 1.5ml / 0.5ml or 6x5ml tubes

8. Disposable tubes ensure no threat of cross-contamination

9. Most samples can be processed in 35 seconds or less

 

Technical Specification 

 1.  Speed Range:       4.0 m/s ~ 7.0 m/s (in steps of 0.05 m/s)

2.  Cycle Duration:       190 s (in step of 1 s)
3.  Pause Time:           0 - 2 minutes  
4.  Acceleration:           ≤ 2s
5.  Deceleration:           ≤ 2s
6.  Programmable:        50 Saved Programs

7.  Number of Cycles:   10

8.  Display:                   Organic-LED, High light and no visual angle limit 

9.  Number of Samples: 1~24 samples (24x2ml / 1.5ml / 0.5ml) or 1~6 samples (5ml tubes)

10. Running Noise:        < 68db

11. Weight:                   25kg

12. Compliance:            CE Compliance
13. Dimensions:            280 x 360 x 385mm (W x D x H)


Typical Samples
- Human, animal, plant cells
- Micro-organisms
- Soil and sediments
- Swabs and feces
- Drugs, polymers, lotions, etc.

 

Samples Preparations:

As heat generated by grinding process will make part of sample tissue damaged, we recommend:

1. After putting the sample into the sample tube, please preserve the sample for 6~12 hours at low temperature (below -60C degree)
2. Then take out for grinding to make the effects achieve the best

 

Code                       Description

LAB-13010-00      AC100~240V 50/60Hz
AS-13011-01           Rotor for 24 x 2.0ml
AS-13011-02           Rotor for 6 x 5.0ml
AS-13011-03           2.0ml tubes
AS-13011-04           5.0ml tubes
AS-13011-05           Φ1.4mm Silica beads
AS-13011-06           Φ2.8mm Silica beads
AS-13011-07           Φ3mm Metal beads
AS-13011-08           Φ6mm Metal beads
AS-13011-09           Φ1mm Glass beads
AS-13011-10           Φ3mm Glass beads


PREVIOUS:GelSMART NEXT:Rotary Evaporator