Intelligent Wet and Dry Laser Particle Size Analyzer
Model ID: PSA2308A
Brief introduction:
PSA2308A intelligent full automatic wet&dry laser particle size analyzer adopt laser diffraction theory (Mie and Fraunhofer diffraction), measure size is from 0.01μm to 2000μm(dry 0.1μm-2000μm), Which offer reliable and repeatable particle size analysis for a diverse range of applications. It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, It’s the prior choice for industrial production quality control departments and research institutions.
Main Specifications:
Model Name | PSA2308A | |
Standard | ISO 13320-1:2009,GB/T19007-2016,Q/0100JWN001-2013 Compliance with 21 CFR Part 11 | |
Principle | Laser diffraction principle | |
Analysis | Mie and Fraunhofer scattering | |
Detector Arrangement | Log-spaced array, test angle from 0.015 degree to 145 degree | |
Measuring Range | Wet:0.01μm-2000 μm Dry: 0.1μm-2000μm | |
Silicon Photodetectors | Wet:127 pcs Dry:100 pcs | |
Accuracy error | Wet<1% Dry<1% (CRM D50) | |
Repeatability error | Wet<1% Dry<1% (CRM D50) | |
Light source | Dual lens, He-Ne laser P>3.0 MW (λ= 632.8nm) Auxiliary green semiconductor laser (λ= 405 nm) P>2.0MW , | |
Laser Safety | Class 1 | |
Wet dispersion | Ultrasonic | Frequency:40KHz Power:60W, Time: ≥1S |
Stir | Revolutions Speed: 0-3000RPM (Adjustable) | |
Circulate | Rated Flow:30L/min Rated Power:70W | |
Sample tank | Volume:1000mL | |
Micro- Sample cuvette | Volume: 10mL (Available) | |
Dry dispersion | Dry-turbulence dispersion patent, normal shock wave shear technique | |
Feeding Speed | Adjustable (Variable speed knob) | |
Operation Mode | Full automatic / manual control, freely choose | |
Dispersion medium | Compressed Air, pressure: 0 to 6 bar | |
Optical bench alignment system | Full automatic, precision is up to 0.2um | |
Test Speed per time | Wet: <2 Min Dry : <1min Typical measuring time<10S | |
Outer dimension | L104cm×W44cm×H54cm | |
Net Weight | 70Kg |
Main Features:
1)Wet and dry sample dispersion system Integrated Design
PSA2308 intelligent laser particle size analyzer which is 1st set laser particle size analyzer integrated wet and dry dispersion test in one in China, it successfully resolved the problem of dry and wet technology integration, realize one key to switch, apply to test all the particle size distribution from 0.01μm-2000μm particles.
2) Intelligent full automatic operation system and manual operation mode, freely choose.
With intelligent automatic mode of operation, to achieve a key test, as long as according to the prompt addition of sample, click the "test", all process will be complete automatically,
not only reduce the testing workload, but also eliminate the interference of human factors, to further improve the accuracy and authenticity of testing results.
Wet method: A key to complete water-supply, ultrasonic dispersion, circulation, testing, cleaning, data record, data analysis, save and print are automatically completed, only take 2 mins.
Dry method: A key to complete the dust collecting, air supply, feeding, testing, data processing and other operation, take 1 min.
3) Stable and unique optical path system patented technology
Converging light Fourier transform path system, enables scattering light be not restricted to the lens aperture limit, and Dual-laser orthogonal light technology make use of the semiconductor auxiliary laser extend the test angle from 0.015 degree to 145 degree, ensure receive all the angles of signals.
4) Automatic Optical path alignment System,
The precision of four hybrid stepping motor in the automatic system of optical components, micro precision of 0.1um, the instrument of light path is always at its best to eliminate manually on the light path and the troubles and difficulties but also enhance the accuracy and stability of test results.
5) Full built-in Sample dispersion system.
Auto wet dispersion system, SOP realize one key operation.
set mechanical stirring, ultrasonic dispersion, and circulation path in one, it ensures particles uniform dispersion and distribution, avoids many bad phenomenon, such as uneven distribution of particles, large particles deposit because of the long outer dispersing system tube, And it guarantees the representativeness of test result.
For dry dispersion system, Turbulence dispersion patented technology and Normal shock shearing effect, make particles sufficient dispersion, ensure good test.
6)Instrument Software
Original Unconstrained free fitting patent technology collect scattering data during the measurement process, make particle analysis not be restricted by any functions, truly reflect particles size distribution, The instrument provide high precision data with
10Khz data acquisition time.
Software Function:
1, Analysis Mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. meet different demands of particle size statistic in different industries.
2, Statistic Method
Volume Distribution, Quantity Distribution
3, Statistic Comparison
Statistic Several Testing Results to compare and analyze
Get difference by compare test result of different batches of samples, samples before and after processing, and different time.
Have great practical significance to industrial raw materials quality control
4, User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries.
5, Test Report
Word, Excel, Photo( Bmp), Text etc.
6, Multiple language Support
English (Others are available)
7,Intelligent Operation Mode
Automatically control water inflow, dispersion,test and analysis.
Better Repeatability after remove human-factor
Figure-PSA2308 scheme
Application:
PSA2308 widely used in cement, ceramics, medicines, lotions, paints, dyes, pigments, fillers, chemicals, catalysts, drilling mud, abrasives, lubricants, coal, sediment, dust, cells, bacteria, food additives, pesticides, explosives, graphite, photographic materials, fuel, ink, metal and non-metal powder, calcium carbonate, kaolin, coal slurry and other powdered materials.
Adopt Patents Technology:
l Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
l Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
l MIE scattering principle application patent No.- ZL 2013 2 0812021.4.
l Dry particle size analyzer full sealed sample cuvette application is protected by patent No.- ZL.2011 2 0267646.8.
l Dual laser beam orthogonal application is protected by patent No.-ZL 2007 2 0025702.0
l Powder dispersion pump design application is protected by patent No.-ZL 2007 2 0018648.7
l Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2
Packing List