Benchtop Spectrophotometer

Product ID: YS6003

YS6003 desktop spectrophotometer can accurately measure and express various color difference formulas and color indexes in a variety of color spaces. The built-in temperature sensor monitors and compensates the test environment to ensure more accurate measurement results. It is widely used in reflection samples, transparent samples color transfer and quality control in plastic electronics, paint and ink, textile and garment printing, printing and other industries.

 

Features:

1, High configuration of hardware: 7 inches TFT Color Capacitive Touch-screen Display; Bluetooth 2.1; Concave Grating.

2, Double Array 256 Image Element CMOS Sensor; Long life-span stable xenon lamp.

3, With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color transmission.

4, Auto identify measuring aperture. Freely switchable between 3 measuring apertures: Φ 25.4mm/8mm/4mm.

5, Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.

6, Wavelength range 360nm – 780nm.It can be used to test fluorescent samples with wide applicability and simple operation

7, Independent light source detector to ensure the light source reliable.

8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users’ requirement.

9, Multiple accessories, sample holders, fixation clamp, suitable to more working condition.

10, Big capacity data storage, for 20000 pieces test result.

11, Built-in camera locating.

12, More powerful extended functions at the PC software.

 

Optical Geometry

Reflect:   di:8°, de:8° (diffused illumination, 8-degree viewing angle);        

SCI   (specular component included)/SCE (specular component excluded);                                         

Include   UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse   illumination: 0° viewing);                      

SCI   (specular component included)/SCE (specular component excluded);                                      

Haze   (ASTM D1003), Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1,   ASTM E1164, DIN5033 Teil7

Application

It is used for accurate analysis and   transmission of laboratory color.    

Apply   in paints, inks, textiles, garments, printing and dyeing, printing etc   industries for color transfer and quality control.

Integrating Sphere Size

Φ154mm

Light Source

360 nm to 780 nm, Combined LED Light (5 million   life span)

Spectrophotometric Mode

Concave Grating

Sensor

256 Image Element Double Array CMOS Image Sensor

Wavelength Range

360-780nm

Wavelength Interval

10nm

Semiband Width

10nm

Measured Reflectance Range

0-200%

Measuring Aperture

Reflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;

Transmissive: Φ30mm/Φ25mm;                           

Remark: 1. Automatic identification of switch   caliber   

2.   Customized Configuration caliber and lens   position

Specular Component

Reflectance: SCI&SCE / Transmittance:   SCI&SCE

Color Space

CIE LAB,XYZ,Yxy,LCh,CIE   LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99

Color Difference Formula

ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,   DINΔE99,ΔE(Hunter)

Other Colorimetric Index

WI (ASTM E313, CIE/ISO, AATCC, Hunter),

YI (ASTM D1925, ASTM 313),


MI (Metamerism Index),

Staining Fastness, Color Fastness, Color   Strength, Opacity,

8° Glossiness, Gardner Index, Pt-Co Index, 555   Index, Haze (ASTM D1003)

Observer Angle

2°/10°

Illuminant

D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12

Displayed Data

Spectrogram/Values, Samples Chromaticity Values,   Color Difference Values/Graph, PASS/FAIL Result, Color Offset

Measuring Time

About 2.4s (Measure SCI & SCE about 5s)

Repeatability

Spectral reflectance: Φ25.4mm/SCI, Standard   deviation within 0.06% (400 nm to 700 nm: within 0.05%)

Chromaticity value: Φ25.4mm/SCI, Standard   deviation within ΔE*ab 0.01 (When a white calibration plate is measured 30 times   at 5 second intervals after white calibration)                                                                                          

Spectral Transmittance: Φ25.4mm/SCI, Standard   deviation within 0.06% (400 nm to 700 nm: within 0.06%)

Chromaticity value: Φ25.4mm/SCI, Standard   deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30   times at 5 second intervals after white calibration)

Inter-instrument Error

Φ25.4mm/SCI, Within ΔE*ab 0.15 (Average for 12   BCRA Series II color tiles)

Dimension

L*W*H=370x300x200mm

Weight

Approx. 9.6kg

Power

AC 24V, 3A Power adapter power supply

Illuminant Life Span

5 years, more than 3 million times measurements

Display

7-inch TFT color LCD, Capacitive Touch Screen

Data Port

USB & Print serial port

Data Storage

Standard 1000 Pcs, Sample 20000 Pcs

Language

English

Operating Environment

0~40, 0~85%RH (no condensing), Altitude < 2000m

Storage Environment

-20~50, 0~85%RH (no condensing)

Standard Accessory

Power Adapter, User Guide, CD Disk (PC Software),   USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission   black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber

Optional Accessory

Micro-printer, Transmissive Test Component, Micro   Aperture(4mm) transmission test clamp component, Instrument inversion   components

Notes: The specifications are subject to change without   notice. YS6003 quality management software can only be used for data   management

 

INQUIRY