pH/mV/ISE/Conductivity/DO Meter

pH/mV/ISE/Conductivity/DO Meter
Model: ELE-551

Features

1.        Meter meets with the requirement of international GLP standards. Its features up to automatic calibration, automatic temperature compensation, data storage, timing measurement, clock display, RS-232 output, function setting and self-diagnose etc. 

2.        There are three different measurement modes: stable display mode; time measurement mode; continuous measurement mode. 

3.        Automatically recognize 13 kinds of pH buffer solution. User can choose anyone from four series of standard buffer solutions: Europe & USA series, NIST series, CHINA series and Self-defined series. 

4.        High purified water and ammonia added purified water pH measuring mode can be set up, especially suitable for electric power and petrochemical industry 

5.        With EH redox potential measuring mode can directly display ORP value which against standard potential of hydrogen electrode. 

6.        Automatically recognize 8 kinds of conductivity standard solution. User can choose anyone from two series of solutions: Europe & USA series and China series. 

7.        Adopt advanced and original conductivity measurement technology, use 1 pc of conductivity electrode (K=1), it can meet measuring accuracy requirement for range within 0.5μS/cm ~ 200mS/cm by using only one-point calibration.

8.        Automatically select conductivity measurement range, when measuring high pure water, equipment automatically enter into temperature compensation of nonlinear model, especially for electricity, microelectronics and the pharmaceutical industry requirements. 

9.        Equips new type of DO electrode which has function of automatic temperature compensation and automatic salinity compensation as well as automatic air pressure compensation inside meter to make DO measuring mode has temperature, air pressure and salinity automatic compensation, easy to use, accurate to measure. 

10.     Polarogram type DO electrode has special electrode calibration cap. Only needs 3 to 5 minutes for electrode polarization. Electrode adopts combination diaphragm cap which very convenient to use. Each DO electrode equips with three spare diaphragms caps. 

11.     There are 10 kinds of common ions can be selected in the ion concentration measuring mode, user also can self-define other ions. 

12.     Can switch 4 kinds of concentration unit: pX, mol/L, mg/L and ppm 

13.     Meter has the only product serial number. 

14.     Dustproof and waterproof meter meets IP54 standards. All sockets are seal protected by the silica gel caps.

Specifications

pH

Measuring range

Resolution

Accuracy

Input current

Input impendance

Stability

Temp. compensation   range

(-1.999 ~ 19.999) pH

0.1/0.01/0.001 pH

Meter: ±0.002 pH,   connect meter with electrode: ±0.01pH

≤1×10-12 A

≥3×1012 Ω

±0.002 pH/3h

(0 to 100) °C (automatic   or manual)

mV

Measuring   range(mV/ORP/EH)

Resolution

Accuracy

-1999.9mV ~ 0 ~   1999.9mV

0.1mV

±0.03% FS

Ion Concentration

Measuring range

Display unit

Accuracy

Temp. compensation   range

0.00 ~ 14.00 pX

pX, mol/L, mg/L, ppm

Meter: ±0.5 %   reading(monovalent), ±1.0 % reading (bivalent)

0 to 60 °C (automatic   or manual)

Conductivity

Measuring range

 

 

 

 

 

Resolution

Accuracy

Temp. compensation   range

Electrode constant

Reference   temperature

Conductivity:(0.00~20.00) μS/cm (20.0~200.0) μS/cm

(200~2000) μS/cm (2.00~20.00)   mS/cm

(20.0~200.0) mS/cm (200~2000)   mS/cm(K=10)

Resistivity:(0 ~ 100)   MΩ·cm

TDS: (0 ~ 100) g/L

Salinity: (0 ~ 100) ppt

0.01/0.1/1μS/cm 0.01/0.1/1   mS/cm

Meter: ±0.5% FS, connect   meter with electrode: ±0.80% FS

(0 ~ 50) °C   (automatic)

0.1 / 0.5    / 1 / 5 / 10 / 50 / 100 cm-1

25°C, 20°C and 18°C

Dissolved Oxygen

Measuring range

Resolution

Accuracy

Response time

Residual current

Temp. compensation   range

Salinity   compensation range

Air pressure   compensation

Automatic   calibration

Electrode type

(0 ~ 40.00) mg/L(ppm)   (0 ~ 200.0) %

0.1/0.01 mg/L(ppm) 1/0.1   %

Meter: ±0.10 mg/L, connect   meter with electrode: ±0.40 mg/L

 ≤30 s (25°C, 90% response)

≤0.1 mg/L

(0 ~ 45) °C(automatic)  

(0 ~ 45) ppt(automatic)  

(80 ~ 105) kPa(automatic)  

Air saturated by   water; water saturated by air

Polarogram type

Temperature

Measuring range

Resolution

Accuracy

-10°C~ 110°C

0.1°C

5~ 60°C range: ±0.4°C other   range: ±0.8°C

Other Technical Parameters:

Data storage

Storage content

 

Power

Communication   connector

Size and weight

Quality and safety   certification

300 groups

Measuring value   series number, measuring value, temperature, ATC or MTC state, measuring date   and time

DC9V/300mA

RS232

160 × 190 × 70mm/880g

ISO9001:2008, CE and   CMC

Working Condition

Environment   temperature

Environmental   humidity

IP rating

5 ~ 35 °C(0.01grade) 15 ~ 30 °C(0.001grade)

≤75%

IP54 Dustproof   and waterproof

 

Standard kit includes

1.   Model ELE-551 pH/mV/ISE/Cond/DO meter

1set

2.   Model 602 flexible electrode holder

1pc

3.   Model 901 intelligent stirrer

1set

4.   201T-M plastic pH/ATC three-in-one combination electrode

1pc

5.   2503-C glass pH combination electrode

1pc

6.   MP500 temperature electrode

1pc

7.   2401T-M conductivity electrode

1pc

8.   DO500 DO electrode

1pc

9.   Model 6213 double salt bridge reference electrode

1pc

10.   pH standard buffer solution (pH4.00, pH6.86, pH9.18/50ml)

1btl/each

11.   1413μS/cm conductivity standard solution (50 mL)

2btls

12.   9V power adapter (meter use)

1pc

13.   6V power adapter (stirrer use)

1pc

14.   ELE-503 membrane cap (DO electrode use)

3pc

15.   ELE-502 DO electrode inner solution (30 mL)

1btl

16.   Cathode polishing paper

2pcs

17.   B628 stirring bead

3pcs

18.   AA battery

4units

19.   RS-232 communication cable

1pc

20.   ELE-551 communication software disk

1pc

21.   Operation manual

1unit

22.   Brief operation instruction

1unit

23.   Packing List

1pc

 


PREVIOUS:Lab pH Meter NEXT:Portable pH meter