Portable Water Hardness Meter
ELE-300
Introduction:
Portable meter for measurement of water hardness (the total concentration of calcium ion and magnesium ion).
Electrode adopts model 601-F water hardness combination electrode with patent structure. It consists of measurement electrode, reference electrode and temperature probe. Replaceable measuring head, steady potential, fast response, easy to use.
Meter adopts intelligent chip design, automatic calibration, automatic temperature compensation, time display, data storage, low voltage display, etc.
Ability to switch among eight units: mmol/L, mg/L (CaCO3), mg/L (CaO), mmol/L (Boiler), mg/L (Ca). Three options of three units: ofH(France), odH (Germany) and oeH(UK) from WH-Link communication software.
Equipped with B1, B2 and B3 calibration solution.
IP57 waterproof rating, equipped with portable case, calibration solution and other accessories.
Specifications:
Water Hardness | Measuring range
Resolution Accuracy Temp. compensation Calibration Solution
Calibration Mode | (0 ~ 10) mmol/L, (0 ~ 401) mg/L(Ca); (0 ~ 1000) mg/L(CaCO3); (0 ~ 100) ofH(France Degree); (0 ~ 561) mg/L(CaO);??? (0 ~ 56) odH(German Degree); (0 ~ 20) mmol/L(Boiler);? (0 ~ 70) oeH (England Degree)。 0.01 and 0.1 water hardness units ±5% FS (5 ~ 50) °C(automatic) B1 Calibration Solution — 2.00×10-2 mmol/L B2 Calibration Solution — 2.00×10-1 mmol/L B3 Calibration Solution — 2.00 mmol/L (B3Calibration Solution also can be used for the soaking solution of electrode) (a)B1/B2 Calibration—using B1 and B2 Calibration Solution,suitable for < 2.00×10-2 mmol/L low concentration water quality,for example, boiler (b)Calibration—using B2 and B3 Calibration Solution,suitable for general water quality. |
Temperature | Measuring range Resolution Accuracy | 0 ~ 60°C 0.1°C ±0.5°C |
Other Technical Parameter | Data storage Content Storage Power Dimension and weight Quality & safe certificate | 99 groups serial number of measuring value, measuring value, units, temperature, ATC or MTC, date, time and calibration way. Two AA cells(1.5V×2) Meter:(65×120×31)mm/180g; Carry Case: (255×210×50) mm/790g IISO9001:2000 and CE |
working conditions | Ambient temperature ambient humidity | (5~35) °C ≤85%RH |
Standard kits:
1. Model ELE-300 water hardness meter | 1set |
2.Model 601-S water hardness electrode (With two measuring heads and one screw plug) | 1pc |
3. AA cell (1.5V) | 2pcs (included) |
4.100mL hardness calibration solution (B1, B2 and B3) | 1btl/each |
5.20mL test cup | 6pcs |
6. Test cup pedestal | 1pc |
7. Reference solution (30 mL) | 1btl |
8.Tools for filling reference solution | 2pcs |
9.Carring case | 1pc |
10. Operation manual | 1 set |
Contact: Harry
Phone: 00852-82283663
E-mail: info@lab-kits.com
Add: ROOM 1, 16F, EMPRESS PLAZA, 17-19 CHATHAM ROAD, TSIM SHA TSUI, KOWLOON, HONG KONG